humidity problem - will this fix it?

BobDavis88@AOL.COM BobDavis88@AOL.COM
Sat, 27 May 2000 12:32:45 EDT


In a message dated 05/27/2000 5:26:57 AM Pacific Daylight Time, 
RptBob1@AOL.COM writes:

[for verdigris in Steinway action centers]
> Use Protek on the center pins and "flex" them individually until you notice 
>  improved movement.  Some Techs feel this is attacking the problem and the 
>  problem will return.  I agree, but find this is a 4-5 year solution.

The problem absolutely WILL return. Many years ago, in an attempt to keep the 
cost down for the customers, and before I gave up being so stubborn, I did 
many experiments with such parts, including Protek, naphtha cleaning, 
perchlorethelene (with and without ultrasound), and repinning with all of the 
above; even rebushing. It always returned, because the root problem wasn't 
removed, and the more that was  spent on a temporary solution was that much 
more taken from the real fix. Further, Protek will make a difference, but the 
difference can last as little as a few days in some actions.
Bob Davis