Hi Terry, The pedal travel is excessive, glue a felt front rail punching on to the trangular piece of white limit felt on the left hand side of the hammer rail, it should cure the problem. Roger At 05:38 PM 10/01/00 -0800, you wrote: >Hi all, > >I have an older Baldwin console (1967). While considered by Baldwin to be a console, at 40", it does have a partially dropped action, although the keys still "push" rather than pull up on the action. I'm trying to regulate the bridal strap wires, so that the strap will not pull up on the back checks, causing the keys to "wink"..which they do to a great extent. It seems that no matter how far i bend the wire forward, making the tape exceedingly loose, it STILL manages to pull on the backcheck when the the left pedal is depressed. Could this be because the tapes are too old and stiff, and they will pull on the backchecks even before they straighten out and become taught? I have a feeling that the bridal wires are just fine where they're are, and that I just need NEW pliable and soft tapes. Am I on the right track? (In case this is seems like a "no brainer" to all the pros on this list, keep in mind that I'm still a newbie.) Thanks. > >P.S: To All those techs in the the South Bay area of SoCAL: See you at the PTG meeting tomorrow night! > >Terry Peterson >Loas Angeles, CA > > >______________________________________________________________ >Get free Internet service and email at http://www.worldspy.com > Roger Jolly Saskatoon, Canada. 306-665-0213 Fax 652-0505
This PTG archive page provided courtesy of Moy Piano Service, LLC